Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
3.
Clin Res Cardiol ; 113(1): 68-74, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37294310

RESUMO

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic stenosis in patients with intermediate to prohibitive surgical risk. When a single TAVI device fails and cannot be retrieved, TAVI-in-TAVI must be performed acutely, but outcomes of bailout TAVI-in-TAVI have been incompletely appraised. We aimed at analyzing patient, procedural and outcome features of patients undergoing bailout TAVI-in-TAVI in a multicenter registry. METHODS: Details of patients undergoing bailout TAVI-in-TAVI, performed acutely or within 24 h of index TAVI, in 6 international high-volume institutions, were collected. For every case provided, 2 same-week consecutive controls (prior TAVI, and subsequent TAVI) were provided. Outcomes of interest were procedural and long-term events, including death, myocardial infarction, stroke, access site complication, major bleeding, and reintervention, and their composite (i.e. major adverse events [MAE]). RESULTS: A total of 106 patients undergoing bailout TAVI-in-TAVI were included, as well as 212 controls, for a total of 318 individuals. Bailout TAVI-in-TAVI was less common in younger patients, those with higher body mass index, or treated with Portico/Navitor or Sapien devices (all p < 0.05). Bailout TAVI-in-TAVI was associated with higher in-hospital rates of death, emergency surgery, MAE, and permanent pacemaker implantation (all p < 0.05). Long-term follow-up showed that bailout TAVI-in-TAVI was associated with higher rates of death and MAE (both < 0.05). Similar findings were obtained at adjusted analyses (all p < 0.05). However, censoring early events, outlook was not significantly different when comparing the two groups (p = 0.897 for death, and p = 0.645 for MAE). CONCLUSIONS: Bail-out TAVI-in-TAVI is associated with significant early and long-term mortality and morbidity. Thus, meticulous preprocedural planning and sophisticated intraprocedural techniques are of paramount importance to avoid these emergency procedures.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Sistema de Registros , Valva Aórtica/cirurgia , Fatores de Risco
4.
JACC Case Rep ; 4(22): 1534-1541, 2022 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-36444187

RESUMO

Erdheim-Chester disease is a rare clonal non-Langerhans cell histiocytosis with multisystemic involvement. It affects bones, large vessels, and retroperitoneum. Cardiac involvement is one of the main mortality predictors.1 We present an unusual case that debuted with cardiac tamponade and pericardial constriction requiring pericardiectomy for definitive control. (Level of Difficulty: Intermediate.).

5.
J Clin Med ; 11(17)2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36079140

RESUMO

Background: The vast majority of transcatheter valve-in-valve (ViV) mitral procedures have been reported with the SAPIEN family. We aimed to report the preliminary experience with the Myval balloon-expandable device in this setting. Methods: Multicenter retrospective study of high-risk surgical patients with mitral bioprosthesis degeneration undergoing transcatheter ViV implantation with Myval device. Results: A total of 11 patients from five institutions were gathered between 2019 and 2022 (age 68 ± 7.8, 63% women). The peak and mean transvalvular gradients were 27 ± 5 mmHg and 14.7 ± 2.3 mmHg, respectively, and the predicted neo-left ventricular outflow tract (neo-LVOT) area was 183.4 ± 56 mm2 (range: 171 to 221 mm2). The procedures were performed via transfemoral access in all cases (through echocardiography-guided transeptal puncture (81.8% transesophageal, 11.2% intracardiac)). Technical success was achieved in all cases, with no significant residual mitral stenosis in any of them (peak 7.2 ± 2.7 and mean gradient 3.4 ± 1.7 mmHg) and no complications during the procedure. There were no data of LVOT obstruction, migration, or paravalvular leak in any case. Mean hospital stay was 3 days, with one major vascular complication and no stroke. At 6-month follow-up, there was one case with suboptimal anticoagulation presenting an increase in the transmitral gradients (mean 15 mmHg) that normalized after optimization of the anticoagulation, but no other relevant events. Conclusions: Transseptal ViV mitral implantation with the balloon-expandable Myval device was feasible and safe avoiding redo surgery in high-risk patients with bioprosthesis degeneration.

6.
JACC Cardiovasc Interv ; 13(17): 1983-1996, 2020 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-32912458

RESUMO

OBJECTIVES: This study aimed to evaluate the safety and mid-term efficacy of transcatheter aortic valve replacement (TAVR) in the setting of aortic valve (AV) infective endocarditis (IE) with residual lesion despite successful antibiotic treatment. BACKGROUND: Patients with AV-IE presenting residual lesion despite successful antibiotic treatment are often rejected for cardiac surgery due to high-risk. The use of TAVR following IE is not recommended. METHODS: This was a multicenter retrospective study across 10 centers, gathering baseline, in-hospital, and 1-year follow-up characteristics of patients with healed AV-IE treated with TAVR. Matched comparison according to sex, EuroSCORE, chronic kidney disease, left ventricular function, prosthesis type, and valve-in-valve procedure was performed with a cohort of patients free of prior IE treated with TAVR (46 pairs). RESULTS: Among 2,920 patients treated with TAVR, 54 (1.8%) presented with prior AV-IE with residual valvular lesion and healed infection. They had a higher rate of multivalvular disease and greater surgical risk scores. A previous valvular prosthesis was more frequent than a native valve (50% vs. 7.5%; p < 0.001). The in-hospital and 1-year mortality rates were 5.6% and 11.1%, respectively, comparable to the control cohort. After matching, the 1-year III to IV aortic regurgitation rate was 27.9% (vs. 10%; p = 0.08) and was independently associated with higher mortality. There was only 1 case of IE relapse (1.8%); however, 18% of patients were complicated with sepsis, and 43% were readmitted due to heart failure. CONCLUSIONS: TAVR is a safe therapeutic alternative for residual valvular lesion after successfully healed AV-IE. At 1-year follow-up, the risk of IE relapse was low and mortality rate did not differ from TAVR patients free of prior IE, but one-fourth presented with significant aortic regurgitation and >50% required re-admission.


Assuntos
Valva Aórtica/cirurgia , Endocardite Bacteriana/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Infecções Relacionadas à Prótese/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/microbiologia , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/mortalidade , Feminino , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/microbiologia , Doenças das Valvas Cardíacas/mortalidade , Próteses Valvulares Cardíacas/efeitos adversos , Mortalidade Hospitalar , Humanos , Masculino , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Recidiva , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...